Industrial Hood - Interlock C6 Mid-Weight , 1 or 2 ply head, goggle face opening, available in 16", 18" 21" total length
Material Content: | 65% Oxidized Polyacrylonitrile (OPF)/35% artificial tri-blend |
Material Construction: | Interlock Knit |
Material Weight: | 6 oz / yd2(+1 / -.5) |
Material Color: | Navy Blue (Standard) |
Color Options Available: |
4th generation advanced CARBON technology 3 elements needed for fire=Oxygen, Heat, and Fuel Without one element, a fire cannot start or continue When exposed to flame, C6 fibers expand, creating an Oxygen starved environment so fire cannot continue. Material is self extinguishing Inherently flame resistant (no harsh chemical treatments) Odor neutralizing, Anti-Static, Low Heat Conductivity Maintains performance values after laundering Finished to minimize shrinkage Interlock knit allows for stretch and shape retention Interlock knit for smooth, sleek, protective surface
Majestic Fire Apparel is a vertical manufacturer Knitting our own fire retardant materials for over 17 years. We knit, cut, sew, and ship-all from our location in PA. MADE IN USA
NFPA 70E PERFORMANCE SPECIFICATIONS OF ASTM F 1959/F 1959M-06ae1: HRC Level 1 = minimum 5 cal/cm2 to 7 cal/cm2 HRC Level 2 = minimum 8 cal/cm2 to 24 cal/cm2 HRC Level 3 = minimum 25 cal/cm2 to 39 cal/cm2 HRC Level 4 = minimum 40 cal/cm2 and over
Meets CAL-OSHA Requirements Passes Federal Test 191, Method 5903.2; CAL OSHA Sections 3406(d) Complies with OSHA Rule 29 CFR Part 1910, 269
Fabric Performance Values in accordance with NFPA 1971-2013 test report dated 3/15/2013 performed by Underwriters Laboratories
ATPV and HAF values found in accordance with ASTM International Standard Test Method F1959-1999. Tests performed by Hugh Hoagland all weights and measurements are approximate
THERMAL PROTECTIVE PERFORMANCE (TPP) | ||
as received | ||
after 5 washes | ||
HOOD MATERIAL BURST STRENGTH | ||
FLAME RESISTANCE TEST | ||
After Flame | as received | |
after 5 washes | ||
Char Length (wales x courses) | as received | |
after 5 washes | ||
CLEANING SHRINKAGE RESISTANCE TEST | ||
Hood Measurement | ||
Face Opening Measurement | ||
HEAT AND THERMAL SHRINKAGE RESISTANCE TEST | ||
Hood Measurement | as received | |
after 5 washes | ||
Face Opening Measurement | as received | |
after 5 washes | ||
SEAM BREAKING STRENGTH TEST | ||
MELT, DRIP, IGNITE, SEPARATE WHEN EXPOSED TO FLAME | ||
ARC THERMAL PERFORMANCE VALUE (ATPV) | ||
1 ply | 12 cal/cm2 | |
2 ply | ||
3 ply | ||
HEAT ATTENUATION FACTOR (HAF) | ||
1 ply | 82% | |
2 ply | ||
3 ply | ||
MOLTEN METAL SPLASH PROTECTION TEST | ||
Time to 2nd degree burn according to Stoll Curve | 1 ply as received | |
1 ply after laundering | ||
Download the specifications sheet by clicking the link below:
VIEW SPECS ON INTERLOCK C6 NAVY MID WEIGHT MATERIAL
MAJESTIC FIRE APPAREL is able to customize your hood by adding your name, badge number, fire department name, logo. Please contact us for further information.
PLEASE NOTE: Any aftermarket customization or modification done to a Majestic Fire Apparel hood by any other company beyond MFA (the original manufacturer) will VOID the warranty and will also VOID the NFPA compliancy of the hood.
Shown in INT C6 Black Premium Weight Material 21"
ATPV
INT C6 Navy
1 PLY= 12 cal