  • Moisture Membrane MM2 PAC II
  • MM2 Illustration

Moisture Management MM2 PAC II

PART#  MM2 C6/MEL PAC II


Product Description

  • Style: PAC II

  • Overall Length:  21”

  • Design Features: Most Popular

  • Hood Specifications: Long notched shoulder bib design

  • Head Layers of Material: 2

                  Outer Material: Ultra C6

                  Inner Material: Melange 

  • Bib Layers of Material: 2

                   Outer Material: Ultra C6

                  Inner Material: Melange

 

*Please note: Any customization or modification not done by Majestic Fire Apparel will void the hood’s warranty and void the NFPA compliance of the hood.

 

made-in-usa.jpg

 

 

Material Specs

PERFORMANCE VALUES

MM2

Material Content:Ultra C6: 65% Oxidized Polyacrylonitrile Melange: 33% Kevlar / 67% Nomex
Material Construction:Ultra C6: 1 x 1 Rib Knit

Melange: Rochelle Knit

Material Weight:

Ultra C6: 6.5 oz / yd2(+1 / -.5)

Melange: 8.5 oz/yd2 (+1/-.5)

Material Color:Ultra C6: Black (Standard) 

Melange: Yellow (Standard)

Color Options Available:  
 
 
STEAM RESISTING MOISTURE MANAGEMENT LAYERING SYSTEM
Head Design=2 ply material (outer to inner) Ultra C6 outer/Melange inner
Bib Design=2 ply material (outer to inner) Ultra C6 outer/Melange inner
THERMAL PROTECTIVE PERFORMANCE (TPP)
Head Designas received46.7 cal/cm2
 after 5 washes 
Bib Design as received46.7 cal/cm2
 after 5 washes 
HOOD MATERIAL BURST STRENGTH
 Ultra C6402 N
 Melange430 N
FLAME RESISTANCE TEST 
Ultra C6 After Flameas received0 second 
 after 5 washes0 second
Melange After Flameas received0 second 
 after 5 washes0 second
Ultra C6 Char Length (wales x courses)as received4mm x 4mm
  3mm x 3mm
Melange Char Length (wales x courses) after 5 washes5mm x 5mm
  5mm x 3mm
CLEANING SHRINKAGE RESISTANCE TEST
Hood Measurement 0%
Face Opening Measurement 4%
HEAT AND THERMAL SHRINKAGE RESISTANCE TEST
Hood Measurementas received0%
 after 5 washes0%
Face Opening Measurementas received5%
 after 5 washes2%
SEAM BREAKING STRENGTH TEST
  837 N
MELT, DRIP, IGNITE, SEPARATE WHEN EXPOSED TO FLAME
  None

Download the above specifications sheet by clicking the link below:  

DATA SHEETS FOR MM2

  

 

Style Specs

 

MM2 PAC II Hood Specifications 

Unlike any 2 ply "sock hood" on the market 45 TPP -
and that's with just 2 layers of material,
(over 53 TPP after 5 washes)!! 2 ply hood-inner layer being the MOISTURE MANAGEMENT layer
3 elements need for fire = Oxygen, Heat, and Fuel
Without one element, a fire cannot start or continue
When exposed to flame, C6 fibers expand,
creating an Oxygen starved environment
so fire cannot continue. Material is self extinguishing
Odor neutralizing, Anti-Static, Low Heat Conductivity
Wider width for air circulation keeping end user cooler
Generous width and size means less fabric stretch
The more surface area for moisture disbursement, the
quicker moisture will evaporate - keeping end user dry!
Maintains protective properties after washing
Finished to minimize shrinkage
MFA hoods offer the most square inches of protection!
You pick the style , you pick the material - 
CUSTOMIZING your own hood!

Majestic Fire Apparel is a vertical manufacturer
Knitting our own fire retardant materials for over 17 years
We knit, cut, sew, and ship - all from our location in PA
MADE IN USA

Warranty Information
Your protective hood is warranted to be free from defects in material or workmanship for one year. This warranty does not cover normal wear or unusual exposures. This warranty is in lieu of all 
other warranties, expressed or implied, including but not limited to, implied warranties of marketability and / or fitness for a particular purpose. Repair or replacement for breach of this warranty shall be the exclusive remedy available. Majestic Fire Apparel, Inc. shall not be liable for incidental or consequential damages.

Hood Specifications, Hood Dimensions Test, and Hood Opening Size Retention Test are in accordance with NFPA 1971-2013 test report dated 3/15/2013 performed by Underwriters Laboratories
ATPV and HAF values found in accordance with ASTM International Standard Test Method F1959-1999. Tests performed by Hugh Hoagland

DO NOT ALTER, MODIFY, ADD TO, OR CHANGE YOUR PROTECTIVE HOOD DOING SO WILL VIOLATE WARRANTY AND VOIDS NFPA AND UL CERTIFICATION

  

DESIGN
Head Design Traditional head design
Bib(Apron) Design Longer length, notched shoulder bib design
LAYERS
Head Layers2 ply material (outer to inner)Ultra C6/Melange
Bib(Apron) Layers2 ply material (outer to inner)Ultra C6/Melange
LENGTH
Head Length 13"
Bib (Apron) Length 8"
OVERALL LENGTH 21"
FACE OPENING
Full Face Opening Circular Measurement120 mm - 145 mm
Sewn with 1/2" elastic. Elastic is encapsulated in material and cover stitched
Elastic Face Opening stretches to accommodate a circumference of at least 31" (800 mm) for ease of donning, snug fit, and proper seal with SCBA.
BINDING
Binding of same fabric material to enhance design with a finished look
SEAMS
Thread 100% Nomex
Head design with traditional center head seam (comfortable central seam)
Safety lock cover stitch of seams
Seam burst strength tests are unsurpassed in industry - 2x or 3x NFPA minimum!
AIT (ADVANCED INSPECTION THREAD) Hoods regularly have thread that matches the color of the hood (white on white / black on black). When AIT is requested, we use a contrasting thread color, which is especially important for inspection of gear. Any compromise to thread, seams, stitching is easily detected with AIT thread. AIT is available upon request. Contact us for more info.
SIZING
  UNIVERSAL size
LABELING AND USER INFORMATION
OWNER IDENTIFICATION On the label the area of PROPERTY OF: _____. Today every Majestic hood is manufactured with our NEW OWNER ID label. Simply identify your ownership with any permanent marker, directly on label.
Labeling - each hood comes individually labeled to identify fabric, hood style, lot # traceability, DOM, Cleaning and Storage Instructions, and UL Certification.
Users Information Guide - each hood has a Warnings & Users Information Guide attached with imperative information. Please review before wearing.
CLEANING AND STORAGE
Machine wash only using regular detergent. Do not use chlorine bleach or detergents containing chlorine. Do not use fabric softeners or detergents containing fabric softeners. Water temperature not to exceed 130 degrees F. Do not wring hood. Squeeze hood to remove excess water. Shape and lay flat in a dry, cool, shaded location to dry. Or tumble dry, low heat. Do not commercially dry clean. Do not store your hood in direct sunlight.
CERTIFICATIONS
NFPA 1971-2013 UL Certified
Complies with CAL-OSHA Requirements Sections 3406 and 3410(d) and OSHA Rule 29 CFR Part 1910, 269
ARC Rated hoods comply with NFPA 70E, meeting performance specifications of ASTM F 1959. See material spec sheets for ATPV and HAF values

 

Download the above specifications sheet by clicking the link below:

 

VIEW SPECS ON STYLE MM2

Certifications

  • CERTIFICATION: NFPA 1971-2013, UL Certified. Meets or exceeds Cal/OSHA Standards.

Customization

MAJESTIC FIRE APPAREL is able to customize your hood by adding your name, badge number, fire department name, logo. Please contact us for further information.

PLEASE NOTE: Any aftermarket customization or modification done to a Majestic Fire Apparel hood by any other company beyond MFA (the original manufacturer) will VOID the warranty and will also VOID the NFPA compliancy of the hood.

WARRANTY INFORMATION Your protective hood is warranted, by MFA, Inc., to be free from defects in material and workmanship for one year. This warranty does not cover normal wear or unusual exposures, including abrasive wearing of close-tolerance accessories-such as voice amplifiers. This warranty is in lieu of all other warranties, expressed or implied, including but not limited to, implied warranties or marketability and/or fitness for a particular purpose. MFA, Inc. shall not be liable for incidental or consequential damages.

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Write your own product review


Recent Updates

Newsletter